Remi Centrifuge R 8c User Manual
- Remi Centrifuge R-8c Service Manual
- Remi Centrifuge R-8c User Manual
- Remi Centrifuge R-8c Bl Manual
- Remi Centrifuge R-8c Plus Manual
MICROPROCESSOR RESEARCH CENTRIFUGES Compufuges model PR-23 & PR-24 are Microprocessor controlled centrifuges used in auxiliary laboratories in industry, Educational & Research institutions, Bio Technology, Medical Laboratories, Hospitals, Blood Banks, Pharmaceutical laboratories and agriculture soil testing for determination of moisture equivalent of soil. MEDICO/CLINICAL CENTRIFUGE PRODUCT DETAILS: A range of centrifuges for general purpose use in Pathology Labs, Small Hospitals, Schools and Colleges. The centrifuge with 5 step speed regulator is provided with Horizontal (Swing Out) Rotor Head. SPECIFICATIONS: Model LI-CEN-40 Max. If you have been looking for Remi R-8C Laboratory Centrifuge (With 8x15 ml Swing Out Head) dealers, your search ends here as you can get the best Remi R-8C Laboratory Centrifuge (With 8x15 ml Swing Out Head) distributors in top cities such as Delhi NCR, Mumbai, Chennai, Bengaluru, Kolkata, Chennai, Pune, Jaipur, Hyderabad and Ahmedabad.
Make Remi Model-R-8C Capacity: 12x15ml Model R-8C capacity:16x15 ml Model -R 8C capacity 12x15 (Not Authorized) Make Remi Model R-8C Not quoted for any equipment Make Altek, multispin centrifuge TC-650F, maintenance free Kasliwal and surana enterprises are eligible in technical bid. Scientific traders is not authorized from Remi. List of Standard Operating Procedures (SOPs) for Quality Control laboratories in pharmaceutical products manufacturing facilities.
It's still there, but a prior update made it invisible for some reason.To get to the equalizer, go to the page that lists the speakers with pictures of each. Apparently there used to be dots to indicate that you could bring up options on the far right of the speaker on the opposite end. Marshall woburn multi room user manual.
Laboratory Products Laboratory Centrifuges Plus
Laboratory Centrifuges model R-8C BL & R-8M are suitable for routine sample analysis in Medical, Hospital, Pathology and Institutional laboratories. With a wide choice of rotor heads and adaptors, these units are truly versatile.
Micro Centrifuges models RM-12C BL & R-12M are ideal for growing routine application in biochemical and clinical labs, for Hematocrit, Corpuscle Percentage contents in blood, Serum analysis and precipitate separation etc.
- Stable speed output even under unstable voltage conditions
- Low sample temperature rise
- High Capacity (R-8C BL / R-8M)
- High Speed (RM-12C BL / R-12M)
- Wide variety of rotors & reduction adaptors
- Brushless Induction motor with frequency drive
- Microprocessor controller with digital display
- Smooth & soft start
- Inverter fault detection with auto shutdown
- 7 segment LED display of speed Digital countdown timer & continuous run
- Dynamic brake for quick deceleration
- Last set parameters recall (Useful for repetitive analysis)
- Automatic door opening
- Stainless Steel centrifuge Chamber, easy to clean
- Safety lid interlock to prevent lid opening during centrifugation
- Imbalance detection & centrifugation stop with display of error
- Motor overload protection
- Gas hinge to prevent door falling
Remi Centrifuge R-8c Service Manual
Models R-8M & R-12M are advanced versions having following additional features:
- Feather touch setting keys
- Alphanumeric LCD display of speed & RCF
- Selection of 3 acceleration & deceleration profiles
Technical Data | |||||||
Models | R-8C BL R-8M | RM-12C BL R-12M | |||||
---|---|---|---|---|---|---|---|
Max. Speed | rpm | 6000 | 16000 | ||||
Max. RCF | ‘g’ | 5070 | 16600 | ||||
Max. Capacity | ml | 400 | 40 | ||||
Digital timer range | Min | 0-59 | 0-15 | ||||
W x D x H | Mm | 380x460x305 | 380 x 460 x 305 |
Remi Centrifuge R-8c User Manual
Supply:220-240Volts 50Hz Single Phase.
Remi Centrifuge R-8c Bl Manual
Rotors Heads Listing for RM-12C BL / R-12M | |||
Models | Capacity | Max. Speed RPM | Max. RCF ‘g’ |
---|---|---|---|
RM-1210 | Micro Hematocrit Rotor for 24 Capillaries (75 X 1 mm) | 12000 | 15300 |
RM-1211 | Micro Hematocrit Rotor for 12 capillaries (QBC -II Plus) | 12000 | 15300 |
RM-1212 | Heparinized capillary tubes (75mm x 1 mm bore) | ||
RM-1213 | Reading Device for RM-1210 | ||
Angle heads | |||
RM-1214 | 10 X 2ml with Glass Tubes & reduction adaptors of 1 ml & 0.5ml | 16000 | 16600 |
RM-1215 | 24 X 1.5ml with Tapered bottom Polypropylene tubes & reduction adaptors of 1 ml & 0.4ml | 11850 | 12715 |
RM-1216 | 8 X 5ml with round bottom Polypropylene tubes & reduction adaptors of 4ml & 2ml | 11850 | 13500 |
RM-1217 | 4 strips of 8 X 0.2ml (PCR Strip Tubes) | 12000 | 11910 |
Rotor Heads Listing for R-8C BL / R-8M | |||||||
Models | Capacity | Max. Speed RPM | Max. RCF ‘g’ | Models | Capacity | Max. Speed RPM | Max. RCF ‘g’ |
---|---|---|---|---|---|---|---|
Swing out Heads (with graduated glass tubes) | Angle Heads (with polypropylene tubes) | ||||||
R-81 | 16 x 15 ml | 4500 | 3485 | R-83 | 16 x 15 ml | 5250 | 4280 |
R-81 A | 12 x 15 ml | 4500 | 3485 | R-83 A | 12 x 15 ml | 5250 | 4280 |
R-81 B | 8 x 15 ml | 4500 | 3440 | R-B3 B | 8 x 15 ml | 6000 | 4700 |
R-82 | 6 x 50 ml | 4500 | 3530 | R-84 | 6 x 50 ml | 6000 | 4700 |
R-82A | 4 x 50 ml | 4500 | 3485 | R-84 A | 4 x 50 ml | 6000 | 4700 |
R-90 (with Biosafety cap] | 4 x 100 ml | 4000 | 2500 | R-88 | 4 x 100 ml | 6000 | 4550 |
R-89 | 24 x 15 ml | 6000 | 5070 |
Remi Centrifuge R-8c Plus Manual
Reduction Adaptors for R-8C BL / R-8M | ||||||||||||||
Models | Capacity | R-81 | R-81 A | R-81 B | R-82 | R-82 A | R-83 | R-83 A | R-83 B | R-84 | R-84 A | R-88 | R-89 | R-90 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
RA-151 | 1 x wintrob | |||||||||||||
RA-152 | 1 x 3ml | |||||||||||||
RA-153 | 1 x 5ml | |||||||||||||
RA-154 | 1 x 8ml | |||||||||||||
RA-155 | 1 x 4ml | |||||||||||||
RA-156 | 1 x 6ml | |||||||||||||
RA-157 | 1 x 50ml | |||||||||||||
RA-158 | 1 x 30ml | |||||||||||||
RA-160 | 1 x 15ml | |||||||||||||
RA-166 | 3 x 15ml | |||||||||||||
RA-501 | 1 x 15 ml | |||||||||||||
RA-502 | 1 x 30ml | |||||||||||||
Suitable for Falcon Tubes (without tubes) | ||||||||||||||
RA-501 F | 1 x 15ml | |||||||||||||
RA-1B0F | 1 x 15ml | |||||||||||||
RA-161F | 1 x 50ml | |||||||||||||
Suitable for Vacutainer Tubes (without tubes) | ||||||||||||||
RA-162 | 1 x upto 5ml (75 mm long) | |||||||||||||
RA-163 | 1 x upto 6ml (100 mm long) | |||||||||||||
RA-164 | 1 x upto 10 ml (100 mm long) | |||||||||||||
RA-167 | 4 x upto 6ml (100 mm long) | |||||||||||||
RA-168 | 3 x upto 10 ml (100 mm long) |